Watermark.
Van Wert
Switch site 38 sites · 11 basins 8 open

Each site is one Watermark investigation. The page color says what opens; the campus line is the build on the ground — two different clocks.

MAU Maumee Basin 9 sites
2MI The Two Miamis 9 sites
SE Southeastern Basins 12 sites
NE Northeast Basins 8 sites
The page — what opens on Watermark Open · Draftfull record Queued · Watchingpreview page Restrictedrequest access
The campus — the build on the ground Investigating Confirmed Under construction Operational
All 38 sites — the network index →
Live

The discharge & the receiving water

Dilution at the design low flows, and the burden the receiving water already carries.

On the record

A real impact study screens the project's discharge against the assimilative capacity of the receiving stream — how much pollutant that stream can take before it breaches a criterion — at the stream's cited design low flows. The design flow matches the criterion type: chronic aquatic-life dilution at the 7Q10, and acute dilution at the 1Q10, which is the sharper single-day design low flow. It also sets that discharge beside what the county's TRI reporters already release. These are screening bands. They are not a permit determination.

The dilution screen · baseline

Discharge → receiving waterDesign 7Q10DischargeChronicCreditedAcute (1Q10)Evidence
Van Wert WWTP→ Town Creek0 cfsOhio EPA NPDES fact sheet 2PD00006 (Van Wert WWTP), Table 12 — USGS 04191500 (Auglaize River Near Defiance, 1915-2003) drainage area ratio applied to Town Creek6 cfs0.03:1 · violation0.02:1 · violation [verified]

1 of 1 receiving reach fails a dilution band at design low flow. The effluent-credited ratio counts the permitted effluent already in the reach (WS-15); a cited 1Q10 of 0 cfs is a stream that runs dry at design low flow — no acute capacity at all.

What the county's TRI reporters already release

EPA RSEI Public Data Set v2.3.12 (EPA gaftp Public Release Data) (v2312) · 15 TRI facilities on file · Van Wert County, OH — comparative Risk-Screening Scores, unitless. [verified]

FacilityCityRSEI score
SONOCO FIBRE DRUM INCVAN WERT399,525.8
KENNEDY MANUFACTURING COVAN WERT187,217.3
DANFOSS POWER SOLUTIONS - VAN WERTVAN WERT94,075.1
FEDERAL MOGUL CORPVAN WERT3,777.7
KENNEDY MANUFACTURING COVAN WERT3,736.3

Any new discharge lands on top of this baseline — the point of reading the two halves together. The full ranked inventory and its reading caveats are in the RSEI annex.

The record behind this chapter

What this chapter stands on: the records it reads, the inputs its modeled figures rest on, and the reference data behind its baselines — the same pages the record screens serve, not a second copy. A figure the record does not support stays [open] and links nothing.

Record groups this chapter reads
Reference data